The PV Grid Parity Initiative
THE INITIATIVE AT A GLANCE
FLEXIBILITY AS OUR FAVORITE APPROACH TO INVESTORS: POSSIBLE ENTERING SCENARIOS
LARGEST PART OF THE PIPELINE BASED IN BASILICATA REGION. THE REASONS
PROCESS CHART PROJECT 1 FS
Region: Basilicata, Italy
Land: Agriculture, 48 hectares
Power: 20MW, single axis tracker
Connection point: 6 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2 M €
Expected IMU yearly tax 3.000 €/MW
PROCESS CHART PROJECT 2 TRIPP
Region: Basilicata, Italy
Land: Agricultural, 45 hectares
Power: 20MW, single axis tracker
Connection point: 4 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2 M€
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 3 GRET
Region: Basilicata, Italy
Land: Agricultural, 48 hectares
Power: 20MW, single axis tracker
Connection point: 6 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2 M€
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 4 PIOM
Region: Tuscany, Italy
Land: Agricultural, 15 hectares
Power: 9,8MW, fixed modules
Connection point: 6 km in MV
Land cost: 2.180€/hectare/year
Est. Total connection costs: 167k€ in Medium Voltage
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 5 SIL
Region: Sardinia, Italy
Land: Agricultural, 15 hectares
Power: 9,8MW, fixed modules
Connection point: 1 km in MV
Land cost: 2.150€/hectare/year
Est. Total connection costs: 167k€ in Medium Voltage
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 6 GUERR
Region: Basilicata, Italy
Land: Agricultural, 47 hectares
Power: 20MW, single axis tracker
Connection point: 5 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2 M€
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 7 TER1
Region: Basilicata, Italy
Land: Agricultural, 50 hectares
Power: 20MW, single axis tracker
Connection point: 7 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2 M€
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 8 TER2
Region: Basilicata, Italy
Land: Agricultural, 50 hectares
Power: 20MW, single axis tracker
Connection point: 7 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2 M€
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 9 MASFOR
Region: Basilicata, Italy (2 plants)
Land: Agricultural, 80 hectares
Power: 20MW + 10 MW, single axis tracker
Connection point: 20 km in HV
Land cost: 2.500€/hectare/year
Est. Total connection costs including substation,
connection line and all infrastructures: <2,8 M€
Expected IMU yearly tax 3.000€/MW
PROCESS CHART PROJECT 10 PST
Region: Basilicata, Italy
Land: Agricultural, 31 hectares
Power: 14 MW, single axis tracker
Connection point: 4 km in HV
Land cost: 43.750€/hectare/ 35 year
Est. Total connection costs including substation, connection line and all infrastructures: 1,8 M€
Expected IMU yearly tax 3.000€/MW
LARGEST PART OF THE PIPELINE BASED IN BASILICATA REGION. THE REASONS
YOUR CONTACT IN GERMANY
|
YOUR CONTACT IN ITALY
|